Please use this identifier to cite or link to this item:
http://hdl.handle.net/123456789/10997
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Eduful, Ernest Kojo | - |
dc.date.accessioned | 2024-08-26T17:14:11Z | - |
dc.date.available | 2024-08-26T17:14:11Z | - |
dc.date.issued | 2021-07 | - |
dc.identifier.uri | http://hdl.handle.net/123456789/10997 | - |
dc.description | ii, ill: 137 | en_US |
dc.description.abstract | Despite refinements in surgical techniques for liver transplantation, liver size disparity remains one of the most common problems in patients. The aim of this study was to establish a relationship between patient liver volume and their body parameters such as Body Mass Index (BMI), Body Surface Area (BSA) and Body Surface Index (BSI), measure the length of the liver in the midclavicular line and also perform dose optimization. The height and weight of patients undergoing for abdominal Computed Tomography (CT) scan were measured. The BSA, BSI and BMI were calculated using their respectively formulas. Using MeVisLab software and CT abdominal images each patient4 s liver volume and the length of the liver in the midclavicular line were measured. Using the SPSS and gender variation, statistical analysis was performed using the null hypothesis to ascertain if there exists a relationship between the calculated body parameters and their respective liver volume. Dose optimization was performed by predicting the effective dose (ED) to the patients even before they are scanned. This was achieved using the peak kilo voltage (kVp) and milli amperes seconds (mAs) to predict signal-to-noise ratio (SNR) and ED to the patient. The average male and female liver volumes measured were 1.356 L and 1.363 L, respectively. The length of the liver in the midclavicular line for male and female were 15.70 ± 2.31 cm and 15.90 ± 2.53 cm, respectively. A model equation, Effective Dose = 36.1 — 0.325 X kVp + 0.2522 X mAs was achieved, and a C# code was written with a Graphic User Interface (GUI) for easy clinical application. | en_US |
dc.language.iso | en | en_US |
dc.publisher | University of Cape Coast | en_US |
dc.subject | Liver volume | en_US |
dc.subject | Dose Optimization | en_US |
dc.subject | Effective Dose | en_US |
dc.subject | Voxel | en_US |
dc.title | Determination of Liver Volume Model of an Adult Ghanaian from Some Selected Health Centers for Clinical Applications and Dose Optimization | en_US |
dc.type | Thesis | en_US |
Appears in Collections: | Department of Physics |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
Eduful 2021.pdf | PhD Thesis | 6.86 MB | Adobe PDF | View/Open |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.