Please use this identifier to cite or link to this item: http://hdl.handle.net/123456789/4575
Title: In vivo transit dosimetry with electronic portal imaging devices (epid) for external beam cancer treatments
Authors: Pokoo-Aikins, Mark
Keywords: ASi EPID
Dose delivery
Dose verification
In vivo dosimetry
Radiotherapy
Transit dosimetry
Issue Date: Jul-2019
Publisher: University of Cape Coast
Abstract: According to the Radiotherapy Risk Profile report by the World Health Organization (WHO), the major causes of severe radiotherapy incidents are due to human errors. The real danger is when the error in administration goes undetected during cancer treatments. This may lead to radiation damage to normal tissues, and may be lethal to the patient. The aim of this work was to develop a transit dosimetry calculation model using C++ and vb.net codes for verifying patient radiation doses using amorphous silicon electronic portal imaging devices (aSi EPID), which could be fast, simple and accurate to be employed in routine clinical work. The model was tested with heterogeneous phantom by comparing the calculations from the developed model with measurements from thermoluminescent dosimeters (TLDs). The transit dosimetry model developed in this study offers satisfying results for square defined fields in real-time treatment of a tissue–mimicking phantom (anthropomorphic phantom). A comparison of absorbed dose measurements between the developed model and TLDs indicate a maximum and a minimum deviations of 3.93% and 1.02% respectively. The calculated absorbed doses from the developed model was therefore in concurrence with TLD measurements within ±5%, and was within the prescribed International Atomic Energy Agency (IAEA) reference level. The model presented therefore satisfied the accuracy requirements for clinical use. The model may therefore be used for in vivo dosimetry of radiation therapy
Description: xx, 139p:, ill.
URI: http://hdl.handle.net/123456789/4578
ISSN: 23105496
Appears in Collections:Department of Physics
Department of Physics
Department of Physics
Department of Physics

Files in This Item:
File Description SizeFormat 
AIKINS 2019.pdfMPhil thesis3.67 MBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.