Please use this identifier to cite or link to this item: http://hdl.handle.net/123456789/8576
Title: Validation of planned radiation absorbed dose for Breast cancer treatment using radiometric film Dosimeter
Authors: Dery, Theresa Bebaaku
Keywords: Dosometry
Hounsfield unit
Monte Carlo
Phantom
Issue Date: Jul-2018
Publisher: University of Cape Coast
Abstract: The essential role of radiotherapy is to ensure detection and treatment of breast Cancers using appropriate doses, these seem not to harm patients under review. Unintended detriments in the treatment and the risk of secondary cancers are Mostly associated with delivering much higher doses than planned dose. This Study focused on using phantoms for the determination, and comparison of Planned doses with actual doses delivered to the breast, during radiation Treatment. Adelaide phantoms were constructed using locally procured Materials to mimic the surrounding tissues of the human female thoracic cavity. Balloons, mango seed, cassava stick and candle were radiologically assessed And used as surrogates for the lung, heart, spinal cord and glandular tissue of the Breast respectively. EBT3 film dosimeter was used with the standard (anthropomorphic) and Adelaide phantoms to measure doses absorbed by the Breast and non-target organs; the doses were delivered from Co-60 and linear Accelerator systems. Monte Carlo N-Particle transport code was also used on a Virtual phantom to compute the dose distribution from the cobalt machine. The Spinal cord absorbed the lowest dose of 0.03 ±0.02 Gy and 0.05+0.01 Gy, while The left lung received the highest doses of 0.74+0.04 Gy and 0.78+0.01 Gy for Co-60 and LINAC respectively. Based on the findings, it was clearly Determined that the target organ received the expected dose within the Acceptable tolerance level of 5%. Additionally, the non-target organs equally Received a minimuim radiation dose according to required standards. A nonclinical Significance differences of planned and delivered doses were achievable Following appropriate quality control both with anthropomorphic and Constructed phantoms.
Description: xxiv 127; 149-156
URI: http://hdl.handle.net/123456789/8576
ISSN: 23105496
Appears in Collections:Department of Physics

Files in This Item:
File Description SizeFormat 
2010_03_03_06_58_07.pdf18.98 MBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.